Chem. J. Chinese Universities ›› 2018, Vol. 39 ›› Issue (4): 636.doi: 10.7503/cjcu20170643

• Analytical Chemistry • Previous Articles     Next Articles

Graphene Oxide/Triangular Gold Nanoplates/Nafion Composite Modified Electrode Used for Sensitive Detection of L-Tryptophan

LI Yuqing1, ZHU Qin1, XIAO Zhongliang1, LÜ Chaozhi1, FENG Zemeng2, YIN Yulong2, CAO Zhong1,*()   

  1. 1. Collaborative Innovation Center of Micro/nano Bio-sensing and Food Safety Inspection,Hunan Provincial Key Laboratory of Materials Protection for Electric Power and Transportation,School of Chemistry and Biological Engineering, Changsha University of Science and Technology,Changsha 410114, China
    2. Institute of Subtropical Agriculture, Chinese Academy of Sciences, Changsha 410125, China
  • Received:2017-09-26 Online:2018-04-10 Published:2018-03-22
  • Contact: CAO Zhong E-mail:zhongcao2004@163.com
  • Supported by:
    † Supported by the National Natural Science Foundation of China(Nos.31527803, 21545010) and the Science and Technology Service-net(STS) Program of the Chinese Academy of Sciences, China(No.KFJ-SW-STS-173)

Abstract:

Uniform triangular gold nanoplates(Au TNPs) with good conductivity were synthesized through a seeded growth process, and then modified on surface of glassy carbon electrode(GCE) using graphene oxide(GO) as carrier and Nafion polyanion as protecting agent, finally forming a nanocomposite modified electrode of GO/Au TNPs/Nafion/GCE. The morphologies of the nanocomposites were characterized by means of scanning electron microscopy and atomic force microscopy. The electrochemical behaviors of L-tryptophan(L-Trp) were investigated via cyclic voltammetry(CV) and differential pulse voltammetry(DPV), indicating that GO/Au TNPs/Nafion composite exhibited excellent electrocatalytic oxidation activity to L-Trp. The DPV method was employed for the determination of L-Trp in 0.10 mol/L PBS(pH=3.5), and a good linear relationship between the peak currents and the concentrations of L-Trp was obtained in the range from 4.000×10-8 to 6.000×10-5 mol/L, with a detection limit of 1.000×10-8 mol/L(S/N=3). Furthermore, the modified electrode possessed good reproducibility, stability and selectivity, which can be used for the determination of L-Trp in pork serum samples with recoveries of 93.1%-105.9%, indicating that the proposed method is valuable in practical application on healthy breeding bio-analysis field.

Key words: L-Tryptophan, Triangular gold nanoplates, Graphene oxide, Nanocomposite electrode

CLC Number: 

TrendMD: