高等学校化学学报 ›› 1990, Vol. 11 ›› Issue (1): 87.

• 研究简报 • 上一篇    下一篇

Luminol-KIO4-Triton X-100一Ru(Ⅳ)化学发光体系的研究及Au-Os-Ru中微量Ru的测定

许晓文, 李玲颖, 胡澄文, 汪蓉   

  1. 南开大学化学系
  • 收稿日期:1988-06-28 出版日期:1990-01-24 发布日期:1990-01-24
  • 通讯作者: 许晓文
  • 基金资助:

    国家自然科学基金

Studies on Luminol-KIO4-Triton X-100-Ru(Ⅳ) Chemiluminescence System and Microdetermination of Ru in Au-Os-Ru Mixture

Xu Xiaowen, Li Ungying, Hu Chengwen, Wang Rong   

  1. Department of Chemistry, Nankm Univerisity, Tianjin
  • Received:1988-06-28 Online:1990-01-24 Published:1990-01-24

摘要: 本文首次用TritonX-100敏化Luminol-KIO4-Ru(Ⅳ)发光体系,配合反相纸色谱法(PTSO为固定相)分离,化学发光法测定了Au-Os-Ru混合液中微量Ru,使Ru(Ⅳ)的检出限降至3.9×10-4μg/mL,比文献[1.2]值降低了近一个数量级。回收率可达95%~106%。

关键词: Ru, 化学发光, Luminol, Triton X-100

Abstract: The sensitization effect of Triton X-100 for the chemiluminescence system of Luminol -KIO4-Ru(Ⅳ) has been first reported. The detection limit of Ru( Ⅳ) has come down to 3.9×10-4μg/ mL. After Au-Os-Ru mixture is separated by reversed phase paper chromatography with di-p-methyl phenyl sulfoxide as the stationary phase,this method can be used in the microdetermination of rutheni-um(Ⅳ). The results of recovery with 95%-106% are satisfactory.

Key words: Ruthenium, Chemiluminescence, Luminol, Triton X-100

TrendMD: