Chem. J. Chinese Universities ›› 1988, Vol. 9 ›› Issue (11): 1114.

• Articles • Previous Articles     Next Articles

Study on the Determination of Trace Manganese by Luminol-Mn(Ⅱ)-KIO4 Ghemiluminescence System

Geng Zheng, Zhang Zhiqi, Bian Lujiao   

  1. Department of Chemistry, Shaanxi Normal University, Xi'an
  • Received:1987-04-02 Online:1988-11-24 Published:1988-11-24

Abstract: Asensitive and selective analytical method has been developed for determination of trace amount of manganese, it bases on luminol-Mn( E )-KIO4 chemiluminescence system and triethanolamine as activator. The detection limit of the method is 8×10-6μg/mL of Mn( Ⅱ). The linear range of the working curves is 10-5~0.1μg/mL. The relative standard deviation is less than ±3%. The method was applied to determination of manganese (Ⅱ) in well water and human hiar with satisfactory results.

Key words: Chemiluminescence, Luminol, Catalysis, Potassium periodate, Triethanolamine (TEA)