高等学校化学学报 ›› 2004, Vol. 25 ›› Issue (9): 1730.

• 研究简报 • 上一篇    下一篇

尿素水溶液还原法去除氮氧化物精制二氧化碳

王树江1, 杨骥2   

  1. 1. 长春工业大学化工学院, 长春130012;
    2. 吉林省环境科学研究院, 长春130012
  • 收稿日期:2003-09-04 出版日期:2004-09-24 发布日期:2004-09-24
  • 基金资助:

    上海宝山钢铁公司科技发展基金(批准号:2000BG001)资助

Refinement of Oxygen Dioxide Through Removing Nitrogen Oxides by Means of Reduced Method of Urea Water Solution

WANG Shu-Jiang1, YANG Ji2   

  1. 1. School of Chemical Engineering, Changchun University of Technology, Changchun 130012;
    2. Jilin China Institute of Environmental Science, Changchun 130012, China
  • Received:2003-09-04 Online:2004-09-24 Published:2004-09-24

关键词: 尿素, 水溶液, 氮氧化物脱除, CO2精制

Abstract: A new process was proposed for removing the nitrogen oxides(NOx) from the CO2 waste gases from the lime torrefied ratary furnace in Shanghai Baoshan Steel and Iron Company by means of absorption method of aqueous urea solution in order to recover highly pure CO2 for producing high quality beverage. The result obtained shows that the concentration of nitrogen oxides can be decreased from 6.5×10-4 mol/L to below 2.0×10-6 mol/L, the removing rate was over 99%. In the experiment, we made NO coming from the reaction NO2 +H2O be all oxidized to NO2 by using a special oxidized method, which was the key step for removing nitrogen oxides.

Key words: Urea, Water solution, Removing of nitrogen oxides, Refinement of CO2

中图分类号: 

TrendMD: