Chem. J. Chinese Universities ›› 1994, Vol. 15 ›› Issue (3): 339.

• Articles • Previous Articles     Next Articles

Studies on the Degradation of Cefotaxime and Voltammetric Behaviour of Degradation Product

LI Qi-Long, CHEN Shou-Ai, SHANG Jun   

  1. Deparment of Chemistry, Beijing Normal University, Beijing, 100875
  • Received:1993-03-06 Revised:1993-05-21 Online:1994-03-24 Published:1994-03-24

Abstract: The degradation of cefotaxime was carried out in NaOHsolution at 100℃ for 20min.Asensitive reduction peak of degradation product was obtained by adsorptive stripping voltammetry in 0.1 mol/L NaOH, at accumulation time of 60 s.Ep=-0.78 V (vs.Ag/AgCl).ip is directly proportional to the concentration of cefotaxime over the range from 1.0×10-9 to 1.0×10-6 mol/L, with a detection limit of 5.0×10-10 mol/L.The voltammetric behaviour of degradation product has been studied.The parameters of electrode reaction have been determined.The mechanisms about the degradation and electrode reactions were discussed.

Key words: Cefotaxime, Degradation, Adsorptive stripping voltammetry