Application of Molecule Wire Polymer in the Determination of Cyanide

ZHAI Qiu-Ge, HUANG Hong-Mei, WANG Ke-Min, TAN Wei-Hong HUANG Shan-Sheng, JIN Yan, LI Bang-Rui   

  1. State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry & Chemical Engineering, Hunan University, Changsha 410082, China
  • Received:2004-03-22 Online:2005-01-10 Published:2005-01-10

Abstract: A new method, molecule wire polymer, was developed for the determination of cyanide based on the competitive reaction. The fluorescence of the molecule wire polymer is quenched due to ion-association with Pd 2+ and restored when cyanide was added into the system. The linear detection range is 5×10-6—2×10-4 mol/L and the detection limit is 1×10-7 mol/L for cyanide under optimal conditions. The possible mechanism of the method was investigated by using absorption spectra. This approach provides a potential useful method for anion detection with a high sensitivity and selectivity.

Key words: Molecule wire polymer, Cyanide, Fluorescence detection