Chem. J. Chinese Universities ›› 1998, Vol. 19 ›› Issue (5): 699.

• Articles • Previous Articles     Next Articles

Determination of Scandium in ETV-ICP-AES by Using PMBP as Chemical Modifier

PENG Tian-You, JIANG Zu-Cheng    

  1. Department of Chemistry, Wuhan University, Wuhan, 430072
  • Received:1997-06-13 Online:1998-05-24 Published:1998-05-24

Abstract: A novel method for the introduction of scandium(Sc), based on the low-temperature volatilization of 1-phenyl-3-methyl-4-benzoyl pyrazolonate(PMBP) chelate from graphite furnace, was reported for electrothermal vaporization(ETV)/ICP-AES. The formation and volatilization of Sc/PMBPchelate in the furnace as well as its affecting factors were investigated in detail. It was found that the existence of extra PMBP was favourable to form the Sc/PMBP chelate and vaporizes/transports quantitatively into ICP. Under optimized conditions, the detection limit was determined to be 0.3 ng/mL. The relative standard deviation (RSD) for 1 ng of scandium was 2.4%(c=0.1 μg/mL, n=7). The scandium content in the standard material vehicle exhaust particulates determined by the proposed method were in good agreement with the reference values.

Key words: ICP-AES, Low-temperature electrothermal vaporization, Scandium/PMBP chelate, Scandium

CLC Number: 