高等学校化学学报 ›› 1996, Vol. 17 ›› Issue (7): 1092.
• 论文 • 上一篇 下一篇
吴臣, 王建刚, 朱毅暋, 李东风
收稿日期:
出版日期:
发布日期:
通讯作者:
作者简介:
基金资助:
吉林省科学技术委员会基金
WU Chen, WANG Jian-Gang, ZHU Yi-Min, LI Dong-Feng
Received:
Online:
Published:
摘要: 报道了铁置换铜的反应原理,通过光电子能谱测定了镀层的成份及含量,确定了体系中可能发生的全反应和副反应,开辟了一条新的镀铜技术路线。
关键词: 浸镀铜, 反应原理, 施镀助剂W-1, 工业应用
Abstract: Fe-Cu replacement reaction under different conditions were studied.The composition of the deposits were detected by PESand XRD.The results showed that under the normal condition,the products of the replacement were mainly Cu2O.All the reactions in the system were disscussed.Some side reactions can be restrained by adding accelerator W-1.Under the controlled condition,good copper plate has been achieved.The result is of great importance to copper plating industry.
Key words: Copper drenching plating, Reaction principle, Accelerator W-1, Industry appli Cation
TrendMD:
吴臣, 王建刚, 朱毅暋, 李东风. 经典铁置换铜反应的研究和工业应用. 高等学校化学学报, 1996, 17(7): 1092.
WU Chen, WANG Jian-Gang, ZHU Yi-Min, LI Dong-Feng. A Study and Industry Application of Classical Fe-Cu Replacement Reaction. Chem. J. Chinese Universities, 1996, 17(7): 1092.
0 / / 推荐