Chem. J. Chinese Universities ›› 2005, Vol. 26 ›› Issue (8): 1424.

• Articles • Previous Articles     Next Articles

Analyses of Seven Kinds of Phenolic Acids in Wine by HPLC with Electrochemical Detection

CAO Wei1,2, SUO Zhi-Rong1, SONG Ji-Rong2, ZHENG Jian-Bin1   

  1. 1. Institute of Analytical Science, Shaanxi Provincial Key Lab of Electroanalytical Chemistry;
    2. College of Chemical Engineering, Northwest University, Xi'an 710069, China
  • Received:2004-09-28 Online:2005-08-10 Published:2005-08-10

Abstract: A rapid, sensitive and accurate reverse phase HPLC-ECD method for simultaneous determination of seven kinds of bioactive phenolic acids(gallic acid, protocatechuic acid, syringic acid, p-coumaric acid, caffeic acid, chlorogenic acid, ferulic acid) in five different types of wine was developed. The separation was performed on Hypersil ODS column(250 mm×4.0 mm, 5.0 μm) by gradient elution. The mobile phase consisted of CH-3OH-4%HAc. The flow rate was 0.8 mL/min. The working potential was 0.7 V and column temperature was 30 ℃. The experimental results showed that the seven kinds of phenolic acids were separated satisfactorily. The detection limit of phenolic acids with ECD was 4-600 times greater than those obtained with UV detection.

Key words: HPLC, Electrochemical detection, Wine, Phenolic acid

CLC Number: 

TrendMD: