Chem. J. Chinese Universities ›› 1993, Vol. 14 ›› Issue (11): 1514.

• Articles • Previous Articles     Next Articles

Calculating Analysis of Acid-Base Titration Without Standard Solution

ZHANG Yun   

  1. Department of Chemistry, Tongji University, Shanghai, 200092
  • Received:1992-12-29 Revised:1993-04-14 Online:1993-11-24 Published:1993-11-24

Abstract: The calculating analysis of titration without standard solution is a method that can be used to determine the concentration of substance titrated and titrant at the same time.In this paper, the calculating analysis of acid-base titration without standard solution has been described for the determination of monobasic acids, polybasic acids and mixed acids with potentiometric titration and the simplex optimization method.The relative error is less than 2% for monobasic and polybasic acids and 10% for mixed acids.

Key words: Analysis without standard solution, Acid-base titration, Potentiometric titration, Simplex optimization method