芯片电泳推拉式压力进样方法

吴志勇, 白晓霞, GAMBY Jeanolivier, GIRAULT H. Hubert   

  1. 洛桑联邦髙等理工学院化学与分子生物学所物理及分析电化学实验室, CH-1015洛桑, 瑞士
  • 出版日期:2004-12-31 发布日期:2004-12-31
  • 通讯作者: 吴志勇,东北大学分析科学研究中心,沈阳110004,E-mail:zhiyongwu2000@yahoo.com E-mail:zhiyongwu2000@yahoo.com

Pressure Sample Introduction in Push-pull Style for Chip Electrophoresis

WU Zhi-Yong, BAI Xiao-Xia, GAMBY Jeanolivier, GIRAULT H. Hubert   

  1. LEPA-ICMB-EPFL, Lausanne, CH-1015, Switzerland
  • Online:2004-12-31 Published:2004-12-31

摘要:

芯片电泳作为微流控分析系统的典型代表,广泛涉及材料、微加工方法、微液流控制、分离模式和检测方法等诸多方面.与传统分析系统一样,样品制备和引入也是微全分析系统实现样品到结果首先面临的问题.

关键词: 芯片电泳, 压力进样法, 推拉式

Abstract:

Chip electrophoresis as a typical microfluidic system involves many aspects,such as substrate material,microfabrication method,control of microfluid,separation modes and detection methods.As in conventional instrumental analyzing system,sample introduction is the first task to be addressed along the line of original sample to answer.Electroinjection has been the main stream method in chip electrophoresis.However,pressure injection method as alternative to electroinjection routinely used in conventional capillary electrophoresis system is seldom used in chip electrophoresis.Comparing to electroinjection,pressure injection is drawing attention in recent years for its major advantages in no electric discrimination and independence to surface charge properties of the sample transfer conduit.A good example of pressure injection for miniaturized capillary electrophoresis may be the successful incorporation of flow injection analysis system,where very high precision was achieved.In the light of typical cross or double T structure of chip electrophoresis,we present here a new sample introduction method based on pressure driven flow.Briefly,by making the inlet and outlet sample flow rates equal,well-defined sample plug was formed in the sampling zone,while the fluidic state in the separation channel remained unaffected.Sample introduction was achieved by stopping the flows upon the application of high voltage in free zone electrophoresis mode.The feasibility and performance were demonstrated by confocal microscope fluorescence detection and imaging with a chip electrophoresis of polymer substrate that was fabricated based on laser ablation and plasma aide adhesiveless bonding.This method was found promising especially for chip electrophoresis;meanwhile,it made the fluidic system more controllable.

Key words: Chip electrophoresis, Pressure sample introduction, Push-pull style