高等学校化学学报 ›› 1999, Vol. 20 ›› Issue (S1): 73.

• Atomic Spectrometry • 上一篇    下一篇

Flow Injection Coupled Capillary Isotachophoresis to ICP-AES and On-line Determination of Metal Species

ZHUANC Zhi-Xia, LI Qi, JIA Li, LI Bo, WANG Xiao-Ru   

  1. Department of Chemistry and the Key Laboratory of Analytical Sciences of MOE, Xiamen University, Xiamen 361005, P. R. China
  • 出版日期:1999-12-31 发布日期:1999-12-31
  • 基金资助:

    Supported by the National Natural Science Foundation of China.

Flow Injection Coupled Capillary Isotachophoresis to ICP-AES and On-line Determination of Metal Species

ZHUANC Zhi-Xia, LI Qi, JIA Li, LI Bo, WANG Xiao-Ru   

  1. Department of Chemistry and the Key Laboratory of Analytical Sciences of MOE, Xiamen University, Xiamen 361005, P. R. China
  • Online:1999-12-31 Published:1999-12-31
  • Supported by:

    Supported by the National Natural Science Foundation of China.

摘要:

A new technique for coupling capillary isotachophoresis (CITP) to Inductive coupled plasmas atomic emission spectrometry (ICP-AES) using flow injection (FI) is developed. Great attention to CITP have been paid owing to its broad application prospect in biochemistry, clinic, pharmacy, food,environment detection and conventional ionic analysis. Its zone-boundary sharpening, large size capillary and self-concentrating effects are different from those of other electrophoretic techniques. Recently, ICP-AES/MS, as a special metal detector, has been combined with the capillary zone electrophoresis (CZE). However, in CZE system, typical sample volume and flow rate are only in the range of 0.02 - 1 μl/min and 0.2-2μl, which results in the difficult for the coupling of CZE and ICP with conventional sampling system and the obtaining enough sensitivity.

Abstract:

A new technique for coupling capillary isotachophoresis (CITP) to Inductive coupled plasmas atomic emission spectrometry (ICP-AES) using flow injection (FI) is developed. Great attention to CITP have been paid owing to its broad application prospect in biochemistry, clinic, pharmacy, food,environment detection and conventional ionic analysis. Its zone-boundary sharpening, large size capillary and self-concentrating effects are different from those of other electrophoretic techniques. Recently, ICP-AES/MS, as a special metal detector, has been combined with the capillary zone electrophoresis (CZE). However, in CZE system, typical sample volume and flow rate are only in the range of 0.02 - 1 μl/min and 0.2-2μl, which results in the difficult for the coupling of CZE and ICP with conventional sampling system and the obtaining enough sensitivity.

TrendMD: