高等学校化学学报 ›› 1999, Vol. 20 ›› Issue (S1): 121.
• Electroanalytical Chemistry • 上一篇 下一篇
Geun Sig Cha, Hyo Jung Yoon, Sung Dong Lee, Gang Cui, Hakhyun Nam
Geun Sig Cha, Hyo Jung Yoon, Sung Dong Lee, Gang Cui, Hakhyun Nam
摘要:
We have recently developed a new type of liquid junction-free reference electrode that is suited for fabrication of miniature ion sensor devices. The proposed reference electrode system employs a solvent-processible polymer membrane, and the best performance membrane so far is formulated with an aromatic type polyurethane,synthesized with 4,4'- methylenebis(phenyl isocyanate) and poly(tetramethylene ether glycol).