高等学校化学学报 ›› 1992, Vol. 13 ›› Issue (9): 1176.

• 论文 • 上一篇    下一篇

MIP-AAS测镍时2种放电-吸收管性能的比较

段忆翔, 杜朝晖, 侯明轶, 刘军, 金钦汉   

  1. 吉林大学化学系, 长春, 130023
  • 收稿日期:1991-10-14 出版日期:1992-09-24 发布日期:1992-09-24
  • 通讯作者: 段忆翔
  • 基金资助:

    国家自然科学基金

Performance Comparison Between Two Different Absorption Cells Used in MIP-AAS for Determination of Nickel

DUAN Yi-Xiang, DU Zhao-Hui, HOU Ming-Yi, LIU Jun, JIN Qin-Han   

  1. Department of Chemistry, Jilin University, Changchun, 130023
  • Received:1991-10-14 Online:1992-09-24 Published:1992-09-24

摘要: 本文以镍为例,分别对MIP-AAS中所使用的T形和L形2种放电-吸收管的性能进行了详细的比较研究。讨论了各种实验参数对不同放电-吸收管的影响差异,从中总结出了一些初步的经验规律.

关键词: 微波诱导等离子体, 原子吸收光谱法, 放电-吸收管, 镍的测定

Abstract: A systematic performance comparison between two different absorption cells used in MIP-AAS for the determination of nickel is completed in this paper.Various factors,such as microwave forward power,carrier gas flow rate,the acidity of the sample solution,etc.,which affected the absorbance,were studied and compared with each other in detail.The effects caused by easily ionized elements and some concomitant elements were also examined for this purpose.A significant enhancement in sensitivity was observed in the determination of nickel when Ca,Mg or La existed.Some conclusions about the performance of T-shaped and L-shaped absorption cells were made

Key words: Microwave induced plasma, Atomic absorption spectrometry, Discharge-absorption cells, Determination of nickel