Chem. J. Chinese Universities ›› 1994, Vol. 15 ›› Issue (11): 1620.

• Articles • Previous Articles     Next Articles

Rapid Detection of Carcinogenicity of Metal Ions by Using O2 Electrode with Bacillus Subtilis Rec-assay Strains

LI Hui1, Diliber1, DENG Jia-Qi1, CHEN Zhong-Fu2   

  1. 1. Chemistry Department, Genetic Research Institute, Frudan university, Shang Hai, 200433;
    2. Genetic Research Institute, Frudan university, Shang Hai, 200433
  • Received:1993-11-29 Revised:1994-04-15 Online:1994-11-24 Published:1994-11-24

Abstract: Asimplified, efficient method has been constructed by combining O2 electrode andBacillus subtilis rec-assay strains to detect genetoxicity of various metal ions. The resultsshow that this method can be used to detect genotoxic metal compounds with a high sensitivity and fidelity, and the carcinogenicity of Cr6+, Co2+, Cd2+, Mn2+ ions are confirmed. Themanipulations are very simple, and reproducible responses was gained within half an hour.So this method can be applied to the screening of environmental metal compounds.

Key words: Genetoxicity, Metal ions, Bacillus subtilis