Chem. J. Chinese Universities ›› 1992, Vol. 13 ›› Issue (7): 998.

• Articles • Previous Articles     Next Articles

Analysis of Linear PS in Microgel Core/Shell Polystyrene Microparticle by TLC,GPC and TLC Scanning

LI Ze-wen1, YANG Bai1, YU Wei-zhong1, SHEN Jia-cong1, DONG Lu-lu2   

  1. 1. Department of Chemistry, Jilin University, Changchun, 130023;
    2. Foundation Department, Haerbin Medical University
  • Received:1991-07-08 Online:1992-07-24 Published:1992-07-24

Abstract: Thin-layer chromatography(TLC) and GPC were used to analyze linear PS in the mi-crogel core/shell polystyrene microparticle.Linear PSwas separated from crosslinking component by TLC, its molecular weight (MW) is 104~105 by GPC.The content of linear PSin the sample can be calculated directly with the area value of TLCscanning, when the weight of the sample was controlled under 1.6× 10-6 g; Combining the MW and content of linear PS with apparent viscosity of the sample, structure of the particles was analyzed qualitatively.

Key words: Microgel core/shell polystyrene microparticle, Separation of linear PS, TLC, GPC, TLC scanning