摘要:

用毛细管色谱柱进行定量分析,必须测定正确的"定量校正值"。本文提出了用标准的二元混合物测定这种校正值的方法;并探讨了不同的操作条件对定量校正值的影响。

Abstract:

It is necessary to determine the accurate "quantitative correction values" in the quantitative analysis by open tubular column chromatography. A new method of determination of these values has been established in this paper with the aid of standard binary mixtures.The "quantitative correction values" obtained from the standard binary mixtures by calculation are in agreement with the experimental ones.The relation between "quantitative correction values" and operational conditions has been discussed.